COLPITTS OSCILLATOR TRAINER Specification

  • Type
  • Oscillator Trainer
  • Material
  • High Quality FR4 PCB, Standard Electronic Components
  • Size
  • Standard Laboratory Trainer Size
  • Input Voltage
  • 230V AC / 12V DC
  • Color
  • Multi-color PCB
  • Dimension (L*W*H)
  • 220 mm x 135 mm x 60 mm (approx)
  • Capacity
  • Single Unit Demonstration
  • Noise Level
  • Low (dependent on amplifier & circuit design)
  • Display
  • Test Points for External Oscilloscope Connection
  • Power Supply
  • Dual Mode: Mains (230V) & Battery (12V DC)
  • Safety
  • Fuse Protected, Short Circuit Protection
  • Oscillator Type
  • Colpitts Oscillator
  • Output Waveform
  • Sinusoidal
  • Connections
  • On-board Test Points and Patch Sockets
  • Components Included
  • Transistors, Inductors, Capacitors, Resistors, Terminals
  • Frequency Range
  • Audio Frequencies, typically 1kHz to 100kHz
  • Accessories
  • Patch Cords, Manual
  • Usage
  • Educational, Laboratory Demonstration
  • Build
  • Mounted on Acrylic Base with Printed Circuit Layout
  • Operating Conditions
  • Room Temperature
 
 

COLPITTS OSCILLATOR TRAINER About



Discover the COLPITTS OSCILLATOR TRAINER-a masterful educational solution designed for monumental demonstration of audio frequency oscillators. This trainer is built using high-quality FR4 PCB, impeccable standard electronic components, and a robust acrylic base with a printed circuit layout. Highly favored in laboratories across India, it delivers fresh, sinusoidal signals via onboard test points and patch sockets. Safety is paramount with fuse protection and short-circuit prevention. Compatible with both mains and battery sources, it's ideal for single-unit demonstration and instruction. Find seamless operation, favorable reviews, and a low noise level in every unit.

Versatile Applications in Education and Demonstration

Used as a comprehensive teaching aid, the COLPITTS OSCILLATOR TRAINER is essential for practical electronics courses, physics labs, and technical institutes. Its application areas include laboratory demonstrations, electronic experiment workshops, and academic sites focusing on signal generation and waveform studies. The trainer excels in environments where a reliable, hands-on approach is required for understanding sinusoidal audio oscillators. It's applied wherever accurate frequency generation and analysis are needed in the curriculum.


Sample, Certification, and Shipping Information

Sample units of the COLPITTS OSCILLATOR TRAINER are available for prospective clients. Upon arrival of your enquiry, certified trainers are prepared for dispatching from India's leading FOB ports. Handover of units is ensured through verified documentation and shipment insurance. All equipment is accompanied by a manual and requisite accessories, adhering to industry certifications aligned with academic and safety standards. This expedites the delivery process and ensures readiness for immediate use.


FAQ's of COLPITTS OSCILLATOR TRAINER:


Q: How is the COLPITTS OSCILLATOR TRAINER used in laboratory demonstrations?

A: It is deployed to demonstrate audio frequency generation, signal waveform analysis, and the operational principles of Colpitts oscillators, enhancing hands-on learning for students in electronic labs.

Q: What components are included with the COLPITTS OSCILLATOR TRAINER?

A: The trainer incorporates transistors, inductors, capacitors, resistors, test points, and patch sockets, all mounted on an acrylic base with a printed circuit layout for clear demonstration.

Q: When can I expect the dispatched oscillators to arrive after placing an order?

A: Following your order, trainers are dispatched from the nearest FOB port in India. Delivery typically aligns with standard shipping lead times, and arrival can be tracked using shipment details provided at handover.

Q: Where can this oscillator trainer be effectively applied?

A: It is most effective in educational institutions, physics laboratories, electronic workshops, and training centers that require robust, demonstrable signal generation tools.

Q: What is the process for connecting external measurement devices to the trainer?

A: External oscilloscopes or measurement equipment can be easily connected using the onboard test points and patch sockets, enabling direct observation and analysis of generated sinusoidal waveforms.

Q: How does the trainer ensure safe operation during use?

A: Safety is assured by fuse protection and short-circuit safeguards built into the trainer's design, providing peace of mind during demonstrations and hands-on sessions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SPEED CONTROL OF SEPARATELY EXCITED DC MOTOR USING THREE  PHASE DUAL CONVERTER TRAINER

SPEED CONTROL OF SEPARATELY EXCITED DC MOTOR USING THREE PHASE DUAL CONVERTER TRAINER

Color : Blue and White

Type : Other, Speed Control Trainer for DC Motor

Dimension (L*W*H) : Approx. 600mm x 400mm x 300mm

Capacity : Suitable for up to 1 HP DC Motor

Input Voltage : 415V AC, 50Hz, 3 Phase

Size : Desktop Laboratory Unit

SINGLE PHASE SERIES INVERTER USING SCR

SINGLE PHASE SERIES INVERTER USING SCR

Color : Green (PCB) / Silver (Terminals)

Type : Other, Single Phase Series Inverter

Dimension (L*W*H) : 220 mm x 160 mm x 65 mm

Capacity : 150VA

Input Voltage : 230V AC

Size : Standard

THREE PHASE HALF AND FULL CONTROLLED BRIDGE CONVERTER TRAINER

THREE PHASE HALF AND FULL CONTROLLED BRIDGE CONVERTER TRAINER

Color : Blue and white

Type : Other, THREE PHASE HALF AND FULL CONTROLLED BRIDGE CONVERTER TRAINER

Dimension (L*W*H) : 400 mm x 300 mm x 150 mm

Capacity : Up to 1 kW load

Input Voltage : Three phase, 415V AC, 50Hz

Size : Standard laboratory benchtop

CO-ORDINATE MEASURING MICROSCOPE

CO-ORDINATE MEASURING MICROSCOPE

Color : White & Black

Type : Other, Coordinate Measuring Microscope

Dimension (L*W*H) : Approx. 600 mm x 400 mm x 700 mm

Capacity : Up to 200 mm (sample size)

Input Voltage : 220V AC, 50Hz

Size : Standard laboratory size