FREQUENCY METERS FOR X-BAND BEND Specification

  • Type
  • Frequency Meter for X-Band Bend
  • Material
  • Aluminum Alloy, Precision Components
  • Size
  • Standard X-Band Waveguide Size
  • Input Voltage
  • Not Required (Passive Device)
  • Color
  • Silver / Metallic
  • Dimension (L*W*H)
  • Approx. 150mm x 80mm x 50mm
  • Capacity
  • Detects Frequency Range as Per X-Band
  • Noise Level
  • Negligible / Passive Operation
  • Application
  • Microwave Frequency Measurement
  • Ambient Humidity Tolerance
  • Up to 80% RH
  • Scale Accuracy
  • ±0.05 GHz
  • Connector Type
  • Flanged Waveguide Input & Output
  • Frequency Range
  • 8 GHz to 12 GHz (X-Band)
  • Body Finish
  • Electro-Plated / Anti-Corrosive
  • Dial Type
  • Rotary Analog Scale
  • Operating Temperature
  • -10°C to 50°C
  • Waveguide Interface
  • WR-90
  • Measurement Principle
  • Absorption Type Mechanical Dial
  • Calibration
  • Factory Calibrated
  • Display Type
  • Mechanical Analog
 
 

FREQUENCY METERS FOR X-BAND BEND About



Experience the reduced expenditure on frequency measurement with our sensational Frequency Meters for X-Band Bend (8 GHz to 12 GHz), highly recommended for elite microwave applications. Engineered with precision components and a radiant, electro-plated finish, this mechanical dial device offers unsurpassed scale accuracy of 0.05 GHz. With flanged WR-90 waveguide interfaces, it ensures a last chance opportunity to secure a premium solution for microwave frequency analysis. Factory calibrated for reliability, its anti-corrosive aluminum alloy body guarantees durability and superior performance even under demanding conditions. Perfect for distributors, exporters, manufacturers, suppliers, and traders in India.

Versatile Application Areas & Direction of Use

The frequency meters for X-Band Bend serve a broad range of microwave frequency measurement applications, including field testing, laboratory analysis, and wireless communication setups. Direction of use involves simply connecting the WR-90 waveguide interface and rotating the mechanical dial for accurate analog readings. This elite device is optimized for usage in research, telecom, and defense sectors, providing precise detection for critical environments.


Main Export Markets & Order Completion Process

Our frequency meters are extensively exported to markets across Asia, Europe, and North America. Samples are available for evaluation before order completion, ensuring meticulous satisfaction. Our sample policy ensures swift shipment upon request and minimal expenditure due to our competitive pricing. Once the order is confirmed, shipment is arranged promptly to ensure timely delivery. Reliability and customer satisfaction remain our highest priorities throughout the process.


FAQ's of FREQUENCY METERS FOR X-BAND BEND:


Q: How do I use the Frequency Meter for X-Band Bend?

A: Simply connect the WR-90 flanged waveguide input and output to your microwave setup, then rotate the analog dial to measure frequencies accurately within the 8 GHz to 12 GHz X-Band range.

Q: What are the key application areas for this frequency meter?

A: This device is ideal for microwave frequency measurement in laboratory testing, wireless communication, field applications, and defense electronics where precision and reliability are critical.

Q: When can I request a sample before placing a full order?

A: Samples are available for potential buyers prior to order completion. You can contact us directly to discuss sample policy and arrange shipment according to your requirements.

Q: Where is the Frequency Meter for X-Band primarily exported?

A: Our frequency meters are exported to major markets in Asia, Europe, and North America, meeting international standards for elite microwave applications.

Q: What is the process of calibration and maintenance for the frequency meter?

A: Each unit is factory calibrated for immediate use, requiring minimal maintenance due to its passive mechanical operation and anti-corrosive finish. Periodic cleaning of the waveguide interface ensures optimal performance.

Q: What are the benefits of using a mechanical analog display for frequency measurement?

A: Mechanical analog displays offer high reliability, real-time readings, and durability in both field and laboratory environments without requiring input voltage, making them highly recommended for demanding conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SPEED CONTROL OF SINGLE PHASE INDUCTION MOTOR USING MOSFET BASED PWM HALF BRIDGE INVERTER TRAINER

SPEED CONTROL OF SINGLE PHASE INDUCTION MOTOR USING MOSFET BASED PWM HALF BRIDGE INVERTER TRAINER

Noise Level : < 40 dB (Signal Electronics Only)

Input Voltage : 230V AC, 50Hz

Size : Desktop Laboratory Instrument

Material : Powder Coated Metal Enclosure with Acrylic Top

Type : Other, Electrical/Electronics Trainer

Dimension (L*W*H) : Approx. 450mm x 300mm x 150mm

FIXED POWER SUPPLIES

FIXED POWER SUPPLIES

Noise Level : Low

Input Voltage : 220V AC

Size : Compact

Material : Metal Enclosure

Type : Other, Fixed Power Supply

Dimension (L*W*H) : 240mm x 170mm x 85mm

ANALOG LIGHTWAVE TRANSMITTER AND RECEIVER USING 555 TRAINERS

ANALOG LIGHTWAVE TRANSMITTER AND RECEIVER USING 555 TRAINERS

Noise Level : Low (Application Dependent)

Input Voltage : 230V AC, 50 Hz (via 12V Adapter)

Size : Standard Laboratory Bench Size

Material : PCB, Electronic Components, Acrylic Panel

Type : Other, Educational Trainer Kit

Dimension (L*W*H) : 300 mm x 220 mm x 100 mm

UJT AS RELAXATION OSCILLATOR TRAINER

UJT AS RELAXATION OSCILLATOR TRAINER

Noise Level : Silent Operation

Input Voltage : 230V AC, 50Hz

Size : Standard laboratory size

Material : Highgrade Bakelite Base, PCB, Electronic Components

Type : Other, UJT as Relaxation Oscillator Trainer

Dimension (L*W*H) : Approx. 340 mm x 210 mm x 60 mm



Back to top