Load Cell Transducer
Load Cell Transducer

Load Cell Transducer

Load Cell Transducer Specification

  • Power Supply
  • 5-15 V DC (Excitation Voltage)
  • Display Type
  • Not Included
  • Features
  • High Accuracy, Compact Design, Easy Installation
  • Control Type
  • Analog Signal Output
  • Temperature Resistance
  • -10°C to +40°C
  • Shape
  • Rectangular
  • Accuracy
  • ±0.03% of Rated Output
  • Type
  • Load Cell Transducer
  • Dimension (L*W*H)
  • 200 mm x 35 mm x 35 mm
  • Equipment Type
  • Load Cell
  • Equipment Materials
  • Alloy Steel
  • Material
  • Alloy Steel
  • Application
  • Industrial Weighing, Force Measurement
  • Ultimate Overload
  • 180% of Rated Capacity
  • Protection Class
  • IP67
  • Input Resistance
  • 400 ±20 Ohms
  • Usage Environment
  • Indoor/Outdoor
  • Zero Balance
  • ±1% FSO
  • Output Sensitivity
  • 2.0 mV/V
  • Capacity Range
  • 10 Kg to 200 Kg
  • Safe Overload
  • 150% of Rated Capacity
  • Cable Length
  • 2 meters (Standard)
  • Output Resistance
  • 350 ±5 Ohms
  • Creep
  • <0.03% FSO (30 min)
 
 

Load Cell Transducer About

Load Cell Transducer

Brand Micro Technologies
Capacity 1 Kg to 100 tones
Excitation Voltage 10 V DC (max.)
Sensitivity 1 to 2 mV/V depending on the load cell structure and capacity.
Safe Overload Of Related Capacity 100% of the rated capacity
Hysteresis 0.2% of the rated capacity
Operating Temperature Range +10 deg C to +55 deg C
Strain Gauge Resistance 350 ohms (+/- 2%)
Max. Overload 200% of the rated capacity
Non-Linearity 0.2% of the rated capacity
Electrical Connection Through four cores shielded cable.



Versatile Industrial Applications

Suitable for a wide range of industrial weighing and force measurement needs, this transducer excels in reliability and durability. Its compatibility under diverse environments makes it an ideal choice for factories, warehouses, and field-based measurements across India.


Precision Engineering and Durability

Manufactured from premium alloy steel and offering accuracy within 0.03% of rated output, this load cell ensures consistent, high-precision results. The IP67 protection guards against dust and water, guaranteeing long-term operation even in challenging conditions.


User-Friendly Installation

Installation is straightforward, thanks to its compact rectangular shape and pre-fitted 2-meter cable. Its standard analog signal output ensures easy integration with various weighing control systems, making it ready for immediate use by distributors, exporters, and end-users.

FAQ's of Load Cell Transducer:


Q: How do I install the Load Cell Transducer for optimal performance?

A: Install the load cell on a stable, flat surface using suitable mounting hardware. Ensure the orientation matches the force direction and connect the cable to your analog signal processing system. Maintain proper alignment to achieve precise readings and consult the wiring diagram included in your product documentation.

Q: What are the ideal usage environments for this load cell transducer?

A: This load cell is designed for both indoor and outdoor environments thanks to its IP67 rating. It operates reliably within temperatures ranging from -10C to +40C, making it suitable for most industrial settings in India.

Q: What happens if the load cell experiences overload?

A: The transducer can withstand up to 150% of its rated capacity as safe overload, and up to 180% as ultimate overload. Exceeding these limits may cause permanent damage, so it's important to use the load cell within specified ratings for durability and accuracy.

Q: Where can this transducer be used in industrial applications?

A: It is suitable for industrial weighing systems, force measurement setups, and any application requiring analog output in manufacturing, processing plants, and quality control labs. Its compact design and sturdy material allow seamless integration across various platforms.

Q: What are the benefits of using an alloy steel construction for this load cell?

A: Alloy steel construction provides the transducer with excellent strength, reduced risk of deformation, and improved lifelong durability, making it reliable under heavy usage and harsh industrial conditions.

Q: How accurate is the measurement, and what is the creep performance?

A: The load cell provides high accuracy at 0.03% of its rated output, and its creep is less than 0.03% of full scale output (FSO) over 30 minutes, ensuring stable and reliable measurements during prolonged loading conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware And Equipments Category

(II) Kjeldhal Distillation Units

(II) Kjeldhal Distillation Units

Features : Uniform Heating, Safety Fuses, Easily Replaceable Parts

Control Type : Rotary Regulator

Equipment Type : Laboratory Distillation Unit

Equipment Materials : Stainless Steel, Borosilicate Glass

Material : Stainless Steel & Glass

Shape : Rectangular Base, Vertical Columns

Lab Willey Grinder

Lab Willey Grinder

Features : Heavily constructed, provided with Hopper, Removable Chamber and collecting container, Easy cleaning, Fitted with Safety Cover

Control Type : Manual

Equipment Type : Sample Preparation Grinder

Equipment Materials : Mild Steel with Powder Coating

Material : Stainless Steel Chamber

Shape : Rectangular

OCTOPUS  ZOOLOGY BIOLOGY SPECIMEN

OCTOPUS ZOOLOGY BIOLOGY SPECIMEN

Features : Ready to Use, Sealed for Safe Viewing, Clear Visibility, Durable Jar

Control Type : Manual Handling

Equipment Type : Specimen Bottle

Equipment Materials : Acrylic, Glass Jar

Material : Preserved Biological Octopus in solution

Shape : Rectangular Jar

Pendulum Bob

Pendulum Bob

Features : Corrosion resistant, precision machined, solid build

Control Type : Manual

Equipment Type : Laboratory Equipment

Equipment Materials : Brass

Material : Brass

Shape : Spherical



Back to top