Optical Time Domain Reflectometer (Otdr)
Optical Time Domain Reflectometer (Otdr)

Optical Time Domain Reflectometer (Otdr)

Optical Time Domain Reflectometer (Otdr) Specification

  • Features
  • Lightweight, Portable, Built-in Visual Fault Locator, Event Map, Data Storage, Auto/Manual Test
  • Resolution
  • 0.05 m
  • Humidity
  • 0%95% RH (non-condensing)
  • Operating Voltage
  • 3.7V (Battery), 100240V AC (Adapter)
  • Accuracy
  • 1.0 m
  • Response Time
  • <10 s
  • Automation Grade
  • Semi-Automatic
  • Temperature
  • -10C to +50C (operation), -20C to +70C (storage)
  • Interface Type
  • USB, SD Card
  • Measuring Range
  • Dynamic range up to 32 dB
  • Equipment Type
  • Optical Time Domain Reflectometer (OTDR)
  • Display Type
  • 5 inch Color TFT LCD touchscreen
  • Port Size
  • FC/PC, SC/PC
  • Power Supply
  • Lithium Battery, AC 100-240V, 50/60Hz Adapter
  • Application
  • Fiber Optic Cable Testing, Link Certification, Troubleshooting
  • Test Range
  • 500 m to 250 km
  • Mounting Type
  • Handheld
  • Usage
  • Field Testing, Laboratory, Maintenance
  • Capacity
  • Standard
  • Machine Weight
  • 2.0 kg
  • Test Speed
  • Adjustable, up to 500 m/s
  • Test Stroke
  • Up to 250 km
  • Control Mode
  • Manual/Automatic
  • Attenuation Dead Zone
  • 8 m
  • Laser Safety
  • Class 1 (IEC 60825-1)
  • Pulse Width
  • 5 ns - 20 s
  • Data Storage Capacity
  • Up to 40,000 records
  • Battery Life
  • >8 hours (continuous operation)
  • Event Dead Zone
  • 1.5 m
  • Dimensions
  • 230 x 130 x 60 mm
  • Language Support
  • Multi-language (English/Chinese and others)
  • Dynamic Range
  • 28~32 dB
  • Wavelengths
  • 1310 nm, 1550 nm
 
 

Optical Time Domain Reflectometer (Otdr) About



Discover the outstanding new release Optical Time Domain Reflectometer (OTDR)your top solution for fiber optic cable testing! This illustrious equipment dazzles with its dual-wavelength options (1310/1550 nm), dynamic range up to 32 dB, lightning-fast test speeds, and capacity for 40,000 records. The lightweight, handheld design, robust 8-hour battery, and clear 5-inch color TFT LCD touchscreen make it ideal for field work. With multi-language support, advanced data storage, and built-in Visual Fault Locator, this hot deal ensures precise certifications, troubleshooting, and network maintenance. Perfect for distributors, exporters, manufacturers, suppliers, and traders in India.

Versatile Applications and Directions for OTDR Usage

The Optical Time Domain Reflectometer (OTDR) is pivotal for fiber optic cable testing, link certification, and troubleshooting. Used by telecom engineers, network technicians, and laboratory professionals, it offers fast, accurate testing in the field or lab. Simply connect the device to the fiber optic link using compatible ports, select manual or automatic mode, and initiate testing through the intuitive touchscreen interface. Its portable, semi-automatic design supports efficient maintenance, measurement, and network diagnostics across diverse environments.


Reliable Supply, Flexible Payment & Export Market Reach for OTDR

Our OTDR supply ability assures timely fulfillment of bulk orders for distributors, exporters, and suppliers. Each proposal amount and list price is tailored for seamless business partnerships, catering to both domestic and international export markets. Flexible payment terms are available to suit procurement needs. Samples of this premium device can be arranged upon request to let you evaluate performance before purchase. Secure, efficient order processing supports smooth delivery and solid business relationships.


FAQs of Optical Time Domain Reflectometer (Otdr):


Q: How does the OTDR operate for fiber optic cable testing?

A: The OTDR sends optical pulses along the fiber and measures the reflected signals to determine faults, breaks, or splice losses, providing a graphical event map for easy analysis.

Q: What are the main applications of this OTDR device?

A: This OTDR is ideal for fiber optic cable testing, link certification, network troubleshooting, and maintenance in field, laboratory, and automation settings.

Q: When should I use manual versus automatic testing mode on the OTDR?

A: Manual mode gives you precise control for custom diagnostics, while automatic mode optimizes test parameters for rapid, hassle-free measurementschoose based on the level of detail needed.

Q: Where can the OTDR be used effectively?

A: Its lightweight, handheld design makes it perfect for onsite field testing, laboratory analysis, and maintenance tasks in varied operating environmentsindoors or outdoors.

Q: What are the benefits of the built-in Visual Fault Locator feature?

A: The Visual Fault Locator enables quick identification and localization of fiber breaks and connection issues, significantly improving maintenance efficiency and reducing downtime.

Q: How does data storage work, and what is the maximum capacity?

A: The device can securely store up to 40,000 records, with data exportable via USB or SD card, ensuring comprehensive documentation and traceability for your testing operations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing And Measuring Equipments Category

L.D.R Trainer

L.D.R Trainer

Power Supply : 230V AC, 50 Hz

Display Type : Digital

Equipment Type : L.D.R Trainer

Control Mode : Manual

Number of Specimens : Single

Usage : Laboratory, Technical Institutes

ISI Interlocking Lab

ISI Interlocking Lab

Power Supply : 220V, 50 Hz, Single Phase

Display Type : Digital Display

Equipment Type : Laboratory Testing Equipment

Control Mode : Digital Touch Screen Control

Number of Specimens : 13

Usage : Lab Testing

Analgesiometer With Pid Controller

Analgesiometer With Pid Controller

Power Supply : 230 V AC, 50 Hz

Display Type : Digital LED Display

Equipment Type : Digital Analgesiometer with PID Controller

Control Mode : Microprocessorbased PID Controller

Number of Specimens : Single Specimen at a time

Usage : Laboratory testing of pain sensitivity

Bottling Plant Control Module

Bottling Plant Control Module

Power Supply : 230V AC, 50 Hz

Display Type : Digital LCD

Equipment Type : Bottling Control Module

Control Mode : Digital Automatic

Number of Specimens : 1 10

Usage : Industrial bottling process management



Back to top