PLC Trainer UI PLC 6DA
PLC Trainer UI PLC 6DA

PLC Trainer UI PLC 6DA

PLC Trainer UI PLC 6DA Specification

  • Interface Type
  • USB/Ethernet
  • Measuring Range
  • Digital and Analog Data
  • Frequency
  • 50 Hz
  • Test Range
  • Multiple Simulations
  • Application
  • Educational & Industrial Automation Training
  • Resolution
  • 16-bit Analog Inputs
  • Specimen Size
  • Standard Terminal Block
  • Operating Voltage
  • 24V DC (for PLC Logic)
  • Response Time
  • Fast, Real-Time Response
  • Equipment Type
  • PLC Trainer
  • Accuracy
  • High Precision
  • Display Type
  • LED and 7-Segment
  • Humidity
  • 40% - 85% RH
  • Power Supply
  • 230 V AC, 50 Hz
  • Port Size
  • Standard Interface Ports
  • Temperature
  • 0°C to 50°C
  • Automation Grade
  • Fully Automatic
  • Features
  • On-Board Switches and Indicators, Programming Cable Included
  • Number of Specimens
  • 6 I/O Slots
  • Mounting Type
  • Tabletop
  • Usage
  • PLC Programming and Simulation
  • Capacity
  • For training up to 6 I/O examples
  • Machine Weight
  • 12 kg
  • Test Speed
  • Adjustable
  • Test Width
  • Standard
  • Test Stroke
  • Standard
  • Control Mode
  • Manual & Automatic
  • Operating Environment
  • Indoor, Class B
  • Safety
  • Over-voltage & Short-circuit Protected
  • Programming Support
  • Supports Ladder, FBD, STL
  • Analog Input/Output
  • 2 Analog Inputs, 2 Analog Outputs
  • Included Accessories
  • Connecting Wires, User Manual
  • Processor Type
  • 6DA Digital/Analog Processor
  • Digital Input/Output
  • 6 Digital Inputs, 6 Digital Outputs
  • Chassis Material
  • Powder Coated Metal
  • Expandable
  • Yes, via additional I/O modules
 
 

PLC Trainer UI PLC 6DA About

PLC Trainer UI PLC 6DA

Usage/Application Laboratory
Brand Micro Technologies
Power Supply 230V +-10% @ 50 Hz
PLC Make ABB, Siemens,Delta & Equivalent.
Digital Input / Output 20 DI-24V, 16DO-24V
Analog I / O 4 Analog Input 4-20mA, 0 to 10V, 2 Analog O/P 4-20mA, 0 to 10V
Inbuilt Power Supply 24V @1A, +15V-0-15V @ 500mA
I / O Simulation 10 No.Push button, 10 No. toggle switch 16 No. LED, 4 Nos Potentiometer for analog Input
I / O Termination 4mm banana sockets 22 Nos
PC Interface RS 232 Serial port with cable.
Enclosure (mm) Powder Coated Metal Box. 450(W) X 400(D) X 150(H)



Flexible and Expandable Design

The PLC Trainer is built to accommodate a variety of training scenarios. With 6 I/O slots and support for up to 6 digital and analog data examples, users can simulate multiple automation tasks effectively. The modular design allows seamless expansion through additional I/O modules, ensuring adaptability for evolving learning or industrial requirements.


High Precision Testing and Control

Equipped with 16-bit analog input resolution and fast response times, the PLC 6DA delivers accurate data acquisition and real-time control. The adjustable test speed, dual control modes (manual & automatic), and LED/7-segment display enhance user experience, making testing processes both intuitive and reliable for trainees and professionals alike.


Safe and Durable Construction

Durability is ensured with a powder-coated metal chassis that offers protection against over-voltage and short circuits. The trainer operates reliably within a wide humidity range (40%-85% RH) and temperatures (0C to 50C), suitable for indoor, Class B environments. This robust build promotes safe and long-lasting usage in training centers and automation labs.

FAQ's of PLC Trainer UI PLC 6DA:


Q: How do I set up the PLC Trainer UI PLC 6DA for initial use?

A: Begin by placing the PLC Trainer on a stable tabletop surface. Connect the supplied wires to the standard terminal blocks and ensure the unit is powered using 230 V AC, 50 Hz supply. Refer to the user manual for detailed wiring diagrams and initial configuration steps.

Q: What programming languages are supported on the UI PLC 6DA?

A: The trainer supports programming in Ladder Diagram (LD), Function Block Diagram (FBD), and Statement List (STL). These languages enable flexible programming for a variety of automation projects, with programming support and cables included in the kit.

Q: When should I consider expanding the I/O capacity of the PLC Trainer?

A: Expansion is recommended when your training or automation tasks require more input/output slots than the standard 6 digital and 2 analog I/Os. Additional I/O modules can be integrated easily to meet the demands of advanced simulations or larger-scale industrial automation setups.

Q: Where can the PLC Trainer UI PLC 6DA be used?

A: This PLC Trainer is designed for indoor use in classrooms, training institutes, or industrial automation labs. Its Class B rating and robust construction make it suitable for a wide range of environments across India.

Q: What is the application process for switching between manual and automatic control modes?

A: To toggle between manual and automatic modes, use the on-board switches as outlined in the user manual. Manual mode allows direct user input for testing, while automatic mode enables programmed sequences via ladder, FBD, or STL logic, facilitating versatile operation.

Q: How does using this trainer benefit educational automation programs?

A: Students and trainees gain practical experience with standard industrial automation protocols, learning programming, simulation, and troubleshooting using real hardware. The trainer's precision, high-speed testing, and expandable features make it an invaluable tool for hands-on education in PLC technology.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing And Measuring Equipments Category

Tablet Dissolution

Tablet Dissolution

Test Speed : 20250 rpm

Machine Weight : 45 kg

Equipment Type : Tablet Dissolution Apparatus

Operating Voltage : 220 V

Response Time : Immediate

Control Mode : Microprocessor Controlled

Analgesio meter

Analgesio meter

Test Speed : Adjustable, 10100 mm/min

Machine Weight : 10 kg

Equipment Type : Analgesio Meter

Operating Voltage : 220 V AC

Response Time : <1 second

Control Mode : Microprocessor based digital

ISI Mark Consultant

ISI Mark Consultant

Test Speed : Standard

Machine Weight : As per requirement

Equipment Type : ISI Mark Consultant

Operating Voltage : 220240 V

Response Time : Immediate

Control Mode : Manual/Automatic

9 Channel Data Logger Channel

9 Channel Data Logger Channel

Test Speed : Up to 100 readings/minute

Machine Weight : 8 kg (approx.)

Equipment Type : Electronic Data Logger

Operating Voltage : 110240V AC

Response Time : <200 ms

Control Mode : Manual & Softwarebased



Back to top