SCR FIRING TECHNIQUES (R, RC, UJT)
SCR FIRING TECHNIQUES (R, RC, UJT)

SCR FIRING TECHNIQUES (R, RC, UJT)

SCR FIRING TECHNIQUES (R, RC, UJT) Specification

  • Type
  • SCR Firing Techniques (R, RC, UJT)
  • Material
  • High-grade Electronic Components
  • Size
  • Standard Educational Lab Setup
  • Input Voltage
  • 230 V AC, 50 Hz
  • Color
  • Blue & White
  • Dimension (L*W*H)
  • 340 mm x 240 mm x 135 mm
  • Capacity
  • Designed for demonstration and experimentation
  • Noise Level
  • Silent Operation
  • Display Features
  • Clearly marked circuit block diagrams and test points
  • Compliance
  • Meets IEC and IS Standards for Educational Equipment
  • Usage
  • Ideal for engineering education, lab experiments, and demonstration
  • Circuit Protection
  • Built-in overload and short-circuit protection
  • Weight
  • Approximately 3.8 kg
  • User Manual
  • Detailed operation and experiment manual included
  • Components Included
  • Resistor (R) Firing Circuit, Resistor-Capacitor (RC) Firing Circuit, UJT Firing Circuit, Power Supply, Indicator Lamps
  • Model Name
  • SCR Firing Techniques Trainer
  • Application Area
  • Power Electronics, Electrical Laboratory Training
  • Power Consumption
  • Less than 10W
  • Operating Temperature Range
  • 0°C to 50°C
  • Mount Type
  • Table Top
  • Connectivity
  • Screw Terminals and Synergy Sockets
 
 

SCR FIRING TECHNIQUES (R, RC, UJT) About



Unlock the splendiferous world of power electronics with the must-have SCR Firing Techniques Trainer. This resplendent training device, now available at an exclusive price cut, lets you take advantage of state-of-the-art R, RC, and UJT firing circuits. Crafted with high-grade components, this virtuoso unit is ideal for engineering education, lab experiments, and demonstrations. Enjoy peace of mind with built-in protection features, visible circuit layouts, and comprehensive manuals. Reliable, robust, and compliant, it's your ultimate choice for the modern electrical laboratory. Don't miss this chance to elevate your training setup!

Expansive Application & Competitive Edge

SCR FIRING TECHNIQUES (R, RC, UJT) Trainer finds its niche in power electronics labs and electrical engineering classrooms. Its primary competitive advantages include resplendent design clarity, inbuilt circuit protection, and ease of use, making it highly suitable for demonstration and experimentation. The surface of application extends from premier universities to resplendent vocational institutes, supporting educators and students alike in mastering SCR firing methods with confidence and safety.


Packaging, Market Reach, & Sample Policy

Your order enjoys secure arrival with robust packaging to ensure product integrity. We offer prompt dispatching from our trusted warehouse, keeping your hands-on training schedule intact. The list price is highly competitive for international clients, with strong exports to Asia, Middle East, and Africa. Sample policies are flexible, allowing potential clients a splendiferous opportunity to evaluate performance before commitment, ensuring complete satisfaction with each delivery.


FAQ's of SCR FIRING TECHNIQUES (R, RC, UJT):


Q: How does the SCR Firing Techniques Trainer enhance electrical laboratory training?

A: The trainer covers essential firing techniques for SCRs-R, RC, and UJT-through clear, hands-on demonstrations, enabling students to build a solid foundation in power electronics.

Q: What components are included in the SCR Firing Techniques Trainer package?

A: The product includes R, RC, and UJT firing circuits, power supply, indicator lamps, built-in circuit protection, clear circuit diagrams, test points, and a comprehensive user manual.

Q: When should this equipment be used in the educational curriculum?

A: It is best used during power electronics courses, laboratory experiments, or any training module that requires a practical understanding of SCR firing methods and circuit behavior.

Q: Where can the SCR Firing Techniques Trainer be installed?

A: Designed as a table-top unit, the trainer fits seamlessly into standard engineering labs, classrooms, and technical training institutes-wherever hands-on electrical demonstrations are performed.

Q: What is the process to maintain and ensure longevity of the SCR Firing Techniques Trainer?

A: Regularly inspect for cleanliness, avoid exposure to extreme temperatures, ensure proper connections via screw terminals, and utilize the user manual for optimal operation and troubleshooting.

Q: How can users take advantage of the indicator lamps and test points?

A: Indicator lamps and test points provide visual feedback, helping users observe real-time circuit states and measure parameters accurately, enhancing understanding and safety during experiments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Humidifier Category

SCR SINGLE PHASE HALF CONTROLLED RECTIFIER USING UJT FIRING

SCR SINGLE PHASE HALF CONTROLLED RECTIFIER USING UJT FIRING

Noise Level : Silent Operation

Capacity : Designed for up to 1A load current

Dimension (L*W*H) : Approx. 340mm x 220mm x 100mm

Color : Multicolor (as per image)

Material : Highgrade Electronic Components, PCB, Metal Housing

Size : Laboratory Tabletop Module

PWM SPEED CONTROL OF DC MOTOR (CHOPPER MOTOR CONTROLLER TRAINER)

PWM SPEED CONTROL OF DC MOTOR (CHOPPER MOTOR CONTROLLER TRAINER)

Noise Level : Low (Electronic switching, minimal audible noise)

Capacity : Designed for 12V/24V DC motors up to 2A

Dimension (L*W*H) : Approx. 28 cm x 18 cm x 10 cm

Color : Grey and Blue (Panel & Enclosure)

Material : High quality PCB with electronic components, ABS enclosure

Size : Benchtop, compact design

SPRING CONSTANT (K CONSTNAT) EXPERIMENT SETUP

SPRING CONSTANT (K CONSTNAT) EXPERIMENT SETUP

Noise Level : Silent Operation (Manual Setup)

Capacity : Can Hold weights up to 1 kg

Dimension (L*W*H) : 30 cm x 15 cm x 40 cm

Color : Blue and White

Material : Mild Steel (Frame), Stainless Steel (Spring), Acrylic (Scale Base)

Size : Standard Lab Bench Size

MAXIMUM & MINIMUM THERMOMETER

MAXIMUM & MINIMUM THERMOMETER

Noise Level : Silent/None

Capacity : Records max and min temperatures

Dimension (L*W*H) : Approximately 250mm x 60mm x 30mm

Color : White scale with black markings

Material : Plastic body with Glass Capillary Tubes

Size : Standard laboratory size



Back to top